Katalogu Görüntüle

ND-Narrow Bileşenleri hakkında daha fazla bilgi için lütfen buraya tıklayın, bütün katalogu görüntüleyin ve indirin.

ND / Narrow Diameter Implant

Dar Çaplı diş implantı, sadece 3 mm’lik platform çapı olan, iki parçalı ince gövdeli bir implanttır. Bu implant, ön bölgedeki sınırlı ve dar kret alanları için idealdir. Tepedeki daha sivri dişler ile sonlanan implant yüzeyindeki bol sayıdaki diş, uygulama kolaylığı ve denge sağlamaktadır.

– Facilitates bone growth above the shoulder.
– Long term implant stability.
– Biological repartition of the forces in cortical bone.

– Softens forces to the cortical bone during insertion .
– Cortical bone maintenance.

– Best surface for osseo integration and bone to implant contact.

– Ideal for immediate implant placement.
– Primary stability.

– Protection of the sinus floor, nerve canal and other important anatomical structures during insertion.

– Insertion rate of 1,5mm per rotation.
– Primary stability
– Increased bone to implant contact
– Faster and even insertion while protecting bone structure

– Increased bone to implant contact

– Reduces bone loss
– Better representation of the biological width
– Long term esthetic stability

– Antirotational security

– Non surgical thickening of the peri-implantary tissue
– Facilitation of the papilla reconstruction-technique

– Elimination of micro-movements
– Elimination of screw loosenings

– Hinders exposure of the implant through bone resorption
– Ideal for the esthetic zone
– Long term esthetic stability

– Thread designs adapted to different bone structures that occur along the depth of the implant
– Enhanced surface
– Round but cutting apex design

Diş Implantları

Çap ø 3.0
ø 2,3/9 mm
ND-3009
ø 2,3/11 mm
ND-3011
ø 2,3/13 mm
ND-3013
* All models are supplied with ND Narrow Diameter screw cap included

Purity and precision

Material purity and surface treatment

Material purity starts with the acquisition of raw material from only the most reliable sources of which each lot is accompanied by its own material certificate and is completely traceable at all phases of production and later use. The production facility in which all the implants and components are made is owned and operated by C-TECH and is certified to the highest standards governing the production of dental/medical devices. To maintain these standards, regular and independent audits are performed by the German auditor, TUV Süd. All up to date certificates are available for download on the company website.

The machining of the EL implant is an intricate process due to the precision required for the Morse conical connection and the exterior complexity of the implant. This intricacy requires double the machining time that would be necessary for that of an average implant. Throughout and following each step of the production process, the implants are thoroughly cleaned in 5 seperate cleaning stages, consisting of a total of 20 cleaning cycles. This attention to cleanliness is in order to assure that no risk of any production residue is remaining on the implant surface.

The surface topography is created through a patented acid etching process. The adjacent photos made with a scanning electron microscope (SEM) demonstrate the lack of impurities on the implant surface as well the abundant surface area created through the patented acidification process.

The purity of the grade 4 titanium used for the EL implant and the surface topology were independently verified through an investigation carried out with a scanning electron microscope (SEM) by the University of Cologne and Medical Material Research Center of Berlin, Germany. The investigation demonstrated the highest level of purity and cleanliness resulting in the award of the BDIZ quality seal. This investigation is avaliable in its long form on the C-TECH website.

Precision components

The successful achievement of a Morse lock and cold weld seal in the implant-prosthetic connection depends on high precision machining. A perfect Morse connection will result in a structural integrity and strength that will be as if the 2 parts were fused together and thus will practically eliminate the gap between the implant and the abutment. Accordingly, the C-TECH components are machined to a tolerance of within 10 microns.

This mechanical fusion of the prosthetic part and the implant has 2 important benefits; prevention of the bacterial colonization of the gap, which can lead to bone loss around the implant, as well as the elimination of micro-movements between the implant and abutment and the consequent screw loosening which can lead to prosthetic failure. The SEM photos on the right show different magnifications of the tight abutment and implant connection. The final photo at the bottom, at 1000 X magnification, shows a fine line where the abutment and the implant meet. This practically nonexistent gap is less than the 1,5 microns width of the bacteria to be found in the oral cavity.

Scientific Publications

EL Clinical Study - September 2014 - Innovative dental implant design shows improved success rate, bone stability and esthetic benefits

EL Clinical Study • September 2014 Innovative dental implant design shows improved success rate, bone stability and esthetic benefits A retrospective study over 3 years including 2-year follow-up Henriette Lerner, DMD Director of HL Dentclinic (private practice focussed on implantology) The aim of this research is to retrospectively evaluate an innovative implant and prosthetical

EL Clinical Study - February 2015 - How to combine bone stability and aesthetic benefits through innovative implant design Treatment of a 65-year-old patient

EL Clinical Study • February 2015 How to combine bone stability and aesthetic benefits through innovative implant design Treatment of a 65-year-old patient Henriette Lerner HL DENTCLINIC, Dentist, Baden-Baden, Germany We present a clinical case with extensive aesthetic requirements, illustrating the treatment of a 65-year-old patient with a partial edentular situation with all

(BDIZ EDI) Implant-Study 2014/2015 - March 2015 - Quantitative and qualitative element-analysis of implant-surface by SEM and EDX

(BDIZ EDI) Implant-Study 2014/2015 • March 2015 Quantitative and qualitative element-analysis of implant-surface by SEM and EDX Prof. Dr. Dr. Joachim E. Zöller Interdisciplinary Polyclinic for Oral Surgery and Implantology Dept. for Cranio Maxillofacial and Plastic Surgery, Dr. med. dent. Dirk U. Duddeck Head of Surface Analyses, In cooperation with the European

EL Clinical Study - April 2015 - Bone stability and aesthetics using an innovative implant design

EL Clinical Study • April 2015 Bone stability and aesthetics using an innovative implant design Treatment of a 65-year-old patient by DR HENRIETTE LERNER (HL DENTCLINIC), BADEN-BADEN, GERMANY Implant success today consists of more than just “osseointegration accomplished”. We also have to take into account the aesthetic result. The present clinical case with

Innovatives Dental-Implantat-Design - May 2015 - Improved Success Rate, Bone Stability, Esthetic Advantages

Magazine PIP – Issue:2/2015 • May 2015 Improved Success Rate, Bone Stability, Esthetic Advantages Author: Dr Henriette Lerner HL DENTCLINIC Abstract Implant success nowadays means more than just the achievement of osseointegration. We must also take into account the esthetic results. The present case study shows the treatment of a partially edentulous 65-year-old female

Sohbete başla
Nasıl yardımcı olabiliriz?