Katalogu Görüntüle

GL-Gingival Bileşenleri hakkında daha fazla bilgi için lütfen buraya tıklayın, bütün katalogu görüntüleyin ve indirin.

GL / Livello Gengivale

Diş Eti Seviyesi implantı, dahili altıgen bağlantısı bulunan, konik şekle sahip bir diş implantıdır. İmplant, kortikal koruma için mikro yivli köprü ile donatılmış ve yumuşak dokuların yerleşimi için parlatılmış çıkıntı ile tamamlanmıştır.

The convex implant platform, in conjunction with the concavity of the implant’s base form a “suction cup” fit, once the abutment is tightened into final seating.

Extending down for one millimeter down from the top of the implant platform, the polished surface is ideal for accommodating the gingival tissue.

The micro threads increase functional surfaces, adapting them to the compact cortical bone tissue and safeguard it against aggression from larger threads to be found in conventional implants. The micro-threads are essential to the maintenance of cortical bone height around the implant.

The complete GL family is endowed with a single connection. Independent of the implant diameter, one abutment fits all. Thus reducing system complexity and cost.

The double-helix design sets c-tech Implants apart from the single helix implants by giving them a more symmetrical introduction into the bone. This translates into masticatory load balance which drastically reduces stress. Its symmetry also renders the implant self-centering, eliminating any form of misalignment in terms of the main axis of the osteotomy site. The pitch of the threads allows for an insertion time that is reduced by half.

Protection of the sinus floor, nerve canal and other important anatomical structures during insertion

The implant surface is blasted with aluminum oxide and then subjected to progressive etching using citric acid.
This surface treatment accelerates the osseointegration process by providing a greater and more uniform area of contact between bone and implant while favoring an immediate implant load. The treatment provides for a uniform surface with progressive trabeculation to be achieved. An additional advantage of the citric acid treatment is that it leaves no traces following decontamination, further reducing the risk of implant failure.

Implantes Dentales

Altura 8 mm
ø 3.5/8 mm
CT-3508
ø 4.3/8 mm
CT-4308
ø 5,1/8 mm
CT-5108
Altura 9 mm
ø 3.5/9 mm
CT-3509
ø 4.3/9 mm
CT-4309
ø 5,1/9 mm
CT-5109
Altura 8 mm
ø 3.5/11 mm
CT-3511
ø 4.3/11 mm
CT-4311
ø 5,1/11 mm
CT-5111
Altura 13 mm
ø 3.5/13 mm
CT-3513
ø 4.3/13 mm
CT-4313
ø 5,1/13 mm
CT-5113
Altura 15 mm
ø 3.5/15 mm
CT-3515
ø 4.3/15 mm
CT-4315
ø 5,1/15 mm
CT-5115
* Todos los modelos GL gingival Level se suministran con tapón de rosca incluidos

Scientific Publications

EL Clinical Study - September 2014 - Innovative dental implant design shows improved success rate, bone stability and esthetic benefits

EL Clinical Study • September 2014 Innovative dental implant design shows improved success rate, bone stability and esthetic benefits A retrospective study over 3 years including 2-year follow-up Henriette Lerner, DMD Director of HL Dentclinic (private practice focussed on implantology) The aim of this research is to retrospectively evaluate an innovative implant and prosthetical

EL Clinical Study - February 2015 - How to combine bone stability and aesthetic benefits through innovative implant design Treatment of a 65-year-old patient

EL Clinical Study • February 2015 How to combine bone stability and aesthetic benefits through innovative implant design Treatment of a 65-year-old patient Henriette Lerner HL DENTCLINIC, Dentist, Baden-Baden, Germany We present a clinical case with extensive aesthetic requirements, illustrating the treatment of a 65-year-old patient with a partial edentular situation with all

(BDIZ EDI) Implant-Study 2014/2015 - March 2015 - Quantitative and qualitative element-analysis of implant-surface by SEM and EDX

(BDIZ EDI) Implant-Study 2014/2015 • March 2015 Quantitative and qualitative element-analysis of implant-surface by SEM and EDX Prof. Dr. Dr. Joachim E. Zöller Interdisciplinary Polyclinic for Oral Surgery and Implantology Dept. for Cranio Maxillofacial and Plastic Surgery, Dr. med. dent. Dirk U. Duddeck Head of Surface Analyses, In cooperation with the European

EL Clinical Study - April 2015 - Bone stability and aesthetics using an innovative implant design

EL Clinical Study • April 2015 Bone stability and aesthetics using an innovative implant design Treatment of a 65-year-old patient by DR HENRIETTE LERNER (HL DENTCLINIC), BADEN-BADEN, GERMANY Implant success today consists of more than just “osseointegration accomplished”. We also have to take into account the aesthetic result. The present clinical case with

Innovatives Dental-Implantat-Design - May 2015 - Improved Success Rate, Bone Stability, Esthetic Advantages

Magazine PIP – Issue:2/2015 • May 2015 Improved Success Rate, Bone Stability, Esthetic Advantages Author: Dr Henriette Lerner HL DENTCLINIC Abstract Implant success nowadays means more than just the achievement of osseointegration. We must also take into account the esthetic results. The present case study shows the treatment of a partially edentulous 65-year-old female

Sohbete başla